ProLink PL-C6-PVC-OR — CAT6 U/UTP Cable, 4 Pair 23 AWG, Orange, RIB
7.899,00 EGP
The ProLink PL-C6-PVC-OR is a high-quality CAT6 unshielded U/UTP network cable with 4 twisted pairs of 23 AWG solid copper, a durable orange PVC jacket, and RIB design, delivering reliable connectivity for 1 Gbps Ethernet (1000BASE-T) in offices, data centers, and enterprise networks.
Description
Category 6 U/UTP Cable, 23AWG, PVC, orange jacket, 4 pair count, 305 m
Technical Specifications
| Specification | Value |
|---|---|
| Category 6 U/UTP Cable, 23AWG, PVC, orange jacket, 4 pair count, 305 m | |
| Description | |
| length Reel in a box | |
| Cable Reference | PROLINK Positioning CAT.6 U/UTP |
| Conductor Solid copper wire AWG23 (Ø 0.58mm). | |
| Insulation Polyethylene ≤ Ø 1.1 mm. | |
| Cable lay up 4 pairs to the core, non-metallic cross separator (spline). | |
| Cable construction | |
| Cable core lying Waterproof compound to prevent moisture migration and | |
| water protection. | |
| Sheath Orange, PVC | |
| Primary (Campus), Secondary (Riser), Tertiary (Horizontal) | |
| IEEE 802.3: 10Base-T; 100Base-T; 1000Base-T; | |
| IEEE 802.5 16 MB; ISDN; TPDDI; ATM | |
| Application | |
| IEEE 802.3af-2002: POE; IEEE 802.3at: POE+ | |
| Outdoor installations. Filled with compound to prevent water penetration. | |
| To ensure electrical properties even in continuous wet conditions. | |
| Standards | ISO/IEC 11801.; EN 50288-6-1;IEC 61156-5 EN 50173-1, |
| Water penetration rating | IEC 60794-1-2F5 , method B |
| Fire rating | (PE outer sheath) IEC 60754-2; Smoke classic cation: No |
| Cable designation Industry U/UTP Cat.6 500MHz 4PxAWG23 | |
| Packaging Drum 305 m | |
| Technical Data | Outer diameter Nominal 7.2 mm |
| Weight 20 kg / km | |
| Thermal load 1884 MJ / km | |
| Segregation class b | |
| Mechanical Properties | |
| Electrical Properties (at | |
| 20°C ± 5°C) | |
| Tensile force 100 N | |
| Bending radius ≥ 33 mm during operation (without load) | |
| ≥ 65 mm during installation (with load) | |
| Temperature range During operation -55°C…+ 60°C | |
| During installation -15°C…+ 50°C | |
| DC loop residence ≤ 17.6 Ω / 100 m | |
| Resistance unbalance ≤ 2 % | |
| Test voltage DC, 1 min, core/core 1000 V | |
| Insulation resistance 500 V ≥ 5000 MΩ * km | |
| Capacitance 48 pF / m nom. | |
| Capacitance unbalance ≤ 1500 pF / km | |
| Mean characteristic impedance 100 ± 5 Ω | |
| Nominal velocity of propagation Approx. 67 % | |
| Propagation delay At 1 MHz ≤ 535 ns / 100 m | |
| Delay skew ≤ 20 ns / 100 m | |
| Coupling attenuation ≥ 40 dB | |
| Balance TCL At 1 MHz ≤ 55 dB | |
| At 10 MHz ≤ 40 dB | |
| At 100 MHz ≤ 35 dB | |
| F (MHZ) | Attenuation (Db/100 m) | NEXT (dB) | PS-NEXT (dB) | )ACR-F 1 (dB/100 m) | )PS-ACR -F 1 (dB/100 m) | Return loss (dB) |
| Max | Typ | Max | Typ | Max | Typ | Max | Typ | Max | Typ | Max | Typ |
| 4 | 3.8 | 3.8 | 66 | 71 | 63 | 66 | 58 | 59 | 55 | 56 | 23 | 26 |
| 10 | 6 | 5.6 | 60 | 65 | 57 | 60 | 50 | 50 | 47 | 48 | 25 | 28 |
| 20 | 8.5 | 8.5 | 56 | 60 | 53 | 56 | 44 | 45 | 41 | 42 | 25 | 28 |
| 62.5 | 15.5 | 15.1 | 48 | 56 | 45 | 48 | 34 | 35 | 31 | 32 | 21.5 | 25 |
| 100 | 19.9 | 19.1 | 45 | 50 | 42 | 45 | 30 | 31 | 27 | 28 | 20.1 | 23 |
| 250 | 33 | 32 | 39 | 44 | 36 | 39 | 22 | 23 | 19 | 20 | 17.3 | 20 |
| 450 | – | 44.8 | – | 40 | – | 35 | – | 15 | – | 17 | – | 20 |
Standards / Compliance
- Standards: ISO/IEC 11801.; EN 50288-6-1;IEC 61156-5 EN 50173-1,
MAECENAS IACULIS
Vestibulum curae torquent diam diam commodo parturient penatibus nunc dui adipiscing convallis bulum parturient suspendisse parturient a.Parturient in parturient scelerisque nibh lectus quam a natoque adipiscing a vestibulum hendrerit et pharetra fames nunc natoque dui.
ADIPISCING CONVALLIS BULUM
- Vestibulum penatibus nunc dui adipiscing convallis bulum parturient suspendisse.
- Abitur parturient praesent lectus quam a natoque adipiscing a vestibulum hendre.
- Diam parturient dictumst parturient scelerisque nibh lectus.
Scelerisque adipiscing bibendum sem vestibulum et in a a a purus lectus faucibus lobortis tincidunt purus lectus nisl class eros.Condimentum a et ullamcorper dictumst mus et tristique elementum nam inceptos hac parturient scelerisque vestibulum amet elit ut volutpat.